Electric power tools 36V 200Hz was commonplace in Soviet era factories. It typically operated from a 380V 50 Hz - 36V 200Hz machine converter. The converter consisted of an electric motor and a generator on a common shaft. This allowed for low, safe voltage, galvanic isolation, and the absence of friction parts like coal brushes in the collector motor.
This is a replacement for an industrial pneumatic tool. And in the front part there is not a hammer, but a clutch and torque limiter. Therefore, the switch is locked in the on position. The tip of the screwdriver with guides, which is missing here, is pressed against the screw head, the clutch engages, the screw is tightened, and the clutch begins to slip.
1:34 Hi, lithuanian here. No, not in germany. In a shoe box. You have a spare shoe box and don't throw it away because you can put something in it. Because it's a box. We are very practical people.
I'm blown away by how helpful the comments are. I now know this thing runs on manually-converted (ie a motor from the mains directly spinning a generator)old soviet 380V 50Hz 3-phase to 36V 200Hz 3-phase, to power clutched electric screwdrivers to a set torque for industrial assembly.
i know nothing, but at 18:50 when you realized that it only spins when the bit is pushed in, it reminded me of seeing modern factory videos where they need to screw in 20 different screws on some component and they do it quickly. in those situations, i imagine it's very handy to have the bit stop spinning as soon they pull off, even if the motor is still spinning, so they don't over torque the screw or strip the head as they pull away from it.
So this was an industrial factory tool. Nowhere else on planet earth you will find 36V 200Hz 3 Phase. In central europe 200V 300Hz 3 Phase used to be a thing but I havent come accross that in the wild at all. Its an obsolete system.
здраствуй! ты мог его запустить и более простым способом! там у тебя на столе лежит трехфазный автомобильный генератор его можно заставить выдавать 200 герц 36вольт! ,а инструмент у тебя греется изза того что частотный преобразователь выдает не чистый синус!
36 вольт в СССР считалось безопасным напряжением для работ на проводящем полу. 200Гц позволяют уменьшить габариты инструмента и сделать его непригодным для использования дома (в СССР было принято все воровать с работы)
Germany and Lithuania are fairly close together and East Germany used to be part of the Soviet Union. I wouldn't be surprised if somebody buying Soviet tools to resell regularly spends time at German estate sales etc.
Soviet tools don't have to be your only videos, just an occasional thing when you find something odd or interesting, of which I am sure there is a plentiful amount.
There’s tons of surplus NOS aircraft transformers around that are built to handle higher frequencies. They were used in the early to mid Cold War era to operate radios and other electronics on board.